Vista simple de metadatos

dc.contributorMDPI AG.es_CL
dc.contributor.authorMattar, Cristian [Universidad de Chile]es_CL
dc.contributor.authorNakos, Theodoros [Chile. Universidad Mayor]es_CL
dc.contributor.authorPérez, Waldo [Chile. Universidad Mayor]es_CL
dc.date.accessioned2018-09-07T14:11:45Z
dc.date.available2018-09-07T14:11:45Z
dc.date.issued2016es_CL
dc.identifier.citationBarrientos, C., Mattar, C., Nakos, T., & Perez, W. (2016). Radiometric Cross-Calibration of the Chilean Satellite FASat-C Using RapidEye and EO-1 Hyperion Data and a Simultaneous Nadir Overpass Approach. Remote Sensing, 8(7), 612.es_CL
dc.identifier.issnISSN 2072-4292es_CL
dc.identifier.issnESSN 2072-4292es_CL
dc.identifier.urihttp://www.mdpi.com/2072-4292/8/7/612/pdfes_CL
dc.identifier.urihttp://repositorio.uchile.cl/handle/2250/142381es_CL
dc.identifier.urihttps://doi.org/10.3390/rs8070612es_CL
dc.identifier.urihttp://repositorio.umayor.cl/xmlui/handle/sibum/2764
dc.description.abstractThe absolute radiometric calibration of a satellite sensor is the critical factor that ensures the usefulness of the acquired data for quantitative applications on remote sensing. This work presents the results of the first cross-calibration of the sensor on board the Sistema Satelital de Observacion de la Tierra (SSOT) Chilean satellite or Air Force Satellite FASat-C. RapidEye-MSI was chosen as the reference sensor, and a simultaneous Nadir Overpass Approach (SNO) was applied. The biases caused by differences in the spectral responses of both instruments were compensated through an adjustment factor derived from EO-1 Hyperion data. Through this method, the variations affecting the radiometric response of New AstroSat Optical Modular Instrument (NAOMI-1), have been corrected based on collections over the Frenchman Flat calibration site. The results of a preliminary evaluation of the pre-flight and updated coefficients have shown a significant improvement in the accuracy of at-sensor radiances and TOA reflectances: an average agreement of 2.63% (RMSE) was achieved for the multispectral bands of both instruments. This research will provide a basis for the continuity of calibration and validation tasks of future Chilean space missions.es_CL
dc.description.sponsorshipEste trabajo fue financiado por: Space Operations Group (GOE) y The Aerial Photogrammetric Service (SAF) de Fuerza Áerea de Chile (FACH)es_CL
dc.format.extentARTÍCULO ORIGINALes_CL
dc.language.isoenes_CL
dc.publisherCIENCIASes_CL
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chilees_CL
dc.subjectCIENCIAS DE LA SALUDes_CL
dc.titleRadiometric Cross-Calibration of the Chilean Satellite FASat-C Using RapidEye and EO-1 Hyperion Data and a Simultaneous Nadir Overpass Approaches_CL
dc.typeArtículo o Paperes_CL
umayor.indizadorCOTes_CL
umayor.politicas.sherpa/romeoLicencia color: VERDE (Revista DOAJ. Se puede archivar el pre-print y el post-print o versión de editor/PDF)--DOAJ es una revista de acceso abierto Pre-print del autor: el autor puede archivar la versión pre-print (ie la versión previa a la revisión por pares) Post-print del autor: el autor puede archivar la versión post-print (ie la versión final posterior a la revisión por pares) Versión de editor/PDF: green tick el autor puede archivar la versión del editor/PDF. Condiciones generales: En repositorios de acceso abierto, La versión de editor/PDF puede utilizarse, La fuente editorial debe reconocerse, Creative Commons Attribution License 4.0, Los autores conservan el copyright, Se anima a los autores a enviar sus artículos publicados a los repositorios institucionales// Disponible en: http://www.sherpa.ac.uk/romeo/issn/2072-4292/es/es_CL
umayor.indexadoWOSes_CL
dc.identifier.doi10.3390/rs8070612es_CL]
umayor.indicadores.wos-(cuartil)Q2es_CL
umayor.indicadores.scopus-(scimago-sjr)sin informaciónes_CL


Vista simple de metadatos



Modificado por: Sistema de Bibliotecas Universidad Mayor - SIBUM
DSpace software copyright © 2002-2018  DuraSpace