Vista simple de metadatos

dc.contributor.authorSepúlveda, Adolfo [Univ Mayor, Fac Ciencias, Santiago 7510041, Chile]es_CL
dc.contributor.authorPavez, Cristiánes_CL
dc.contributor.authorCabrini, Nibaldoes_CL
dc.contributor.authorPedreros, José A.es_CL
dc.contributor.authorAvaria, Gonzaloes_CL
dc.contributor.authorSan Martin, Patricio I.es_CL
dc.contributor.authorSoto, Leopoldoes_CL
dc.date.accessioned2020-04-08T14:11:55Z
dc.date.accessioned2020-04-13T18:12:52Z
dc.date.available2020-04-08T14:11:55Z
dc.date.available2020-04-13T18:12:52Z
dc.date.issued2018es_CL
dc.identifier.citationPavez, C., Sepúlveda, A., Cabrini, N., Pedreros, J. A., Avaria, G., San Martín, P. I., & Soto, L. (2018). Energetics X-Ray Burst Observation in the Collapse of an X-Pinch Conducted in a Small Capacitive Generator of Low Impedance. IEEE Transactions on Plasma Science, 46(11), 3829-3836.es_CL
dc.identifier.issn0093-3813es_CL
dc.identifier.issn1939-9375es_CL
dc.identifier.urihttps://doi.org/10.1109/TPS.2018.2876283es_CL
dc.identifier.urihttp://repositorio.umayor.cl/xmlui/handle/sibum/6268
dc.descriptionPresentado a: 10th Dense Z-Pinch Conferenceen: Stateline, NV, AUG, 2017es_CL
dc.description.abstractIn this paper, the experimental results of the behavior of an X-pinch plasma conducted in a small capacitive generator of low impedance and inductance are reported. The generator produces currents of the order of 120 kA in times about 500 ns, when a charging voltage of 24 kV, and wires as load are used. W, Al, and Cu X-pinches of different diameters were tested. The experimental observations show a similar global dynamic to those observed in experiments of higher current and shorter quarter period, with an intense emission of energetics X-rays (> 5 keV) generated by plasma dynamics in the cross point of wires. The fast plasma dynamic is evidenced from the strong change of frequency in the current-derivative signal, which is correlated with the X-ray signals observed from the radiation detectors. From the time-integrated pinhole images and time-integrated aperture images, filtered with different aluminum foils of different thicknesses, an estimated X-ray source size of 70 +/- 20 mu m with energies above 7 keV is obtained.es_CL
dc.description.sponsorshipCONICYT-PIA ACT [172101]; FONDECYTComision Nacional de Investigacion Cientifica y Tecnologica (CONICYT)CONICYT FONDECYT [1151471]es_CL
dc.description.sponsorshipThis work was supported in part by CONICYT-PIA ACT under Grant 172101 and in part by FONDECYT under Grant 1151471. The review of this paper was arranged by Senior Editor F. Beg.es_CL
dc.language.isoenes_CL
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INCes_CL
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Chile
dc.sourceIEEE Trans. Plasma Sci., NOV 2018. 46(11): p. 3829-3836
dc.subjectPhysics, Fluids & Plasmases_CL
dc.titleEnergetics X-Ray Burst Observation in the Collapse of an X-Pinch Conducted in a Small Capacitive Generator of Low Impedancees_CL
dc.typeProceedings Paperes_CL
umayor.facultadCIENCIASes_CL
umayor.politicas.sherpa/romeoSIN INFORMACIÓNes_CL
umayor.indexadoWOS:000450044900014es_CL
umayor.indexadoSIN PMIDes_CL
dc.identifier.doiDOI: 10.1109/TPS.2018.2876283es_CL]
umayor.indicadores.wos-(cuartil)Q4es_CL
umayor.indicadores.scopus-(scimago-sjr)SCIMAGO/ INDICE H: 98 Hes_CL


Vista simple de metadatos



Modificado por: Sistema de Bibliotecas Universidad Mayor - SIBUM
DSpace software copyright © 2002-2018  DuraSpace