Comparación de los niveles de actividad física medidos con cuestionario de autorreporte (IPAQ) con medición de acelerometría según estado nutricional
Fecha
2020-01Autor
Martorell, Miquel
Labraña, Ana María
Ramírez-Alarcón, Karina
Díaz-Martínez, Ximena
Garrido-Méndez, Alex
Rodríguez-Rodríguez, Fernando
Cigarroa, Igor
Vásquez, Jaime
Concha, Yeny
Martinez-Sanguinetti, Maria Adela
Leiva, Ana María
Alvarez, Cristian
Petermann-Rocha, Fanny
Salas-Bravo, Carlos
Celis-Morales, Carlos A. [Univ Mayor, Ctr Exercise Physiol Res CIFE, Chile]
Ubicación geográfica
Notas
HERRAMIENTAS
Resumen
Background: It is unknown if nutritional status could influence the accuracy of self-reported physical activity (PA) levels. Aim: To compare PA measured using the international physical activity questionnaire (IPAQ) and by accelerometry (ActiGraph) according to nutritional status in Chilean adults. Material and Methods: This is an observational cross-sectional study that used information from the GENADIO project carried out in Chile between 2009-2011. The sample consisted of 322 people. PA levels and sitting time were determined through the IPAQ self-report questionnaire and ActiGraph accelerometers (GTM1). The nutritional status was determined according to body mass index (BMI). Results: Compared with the measurement made with accelerometry, the IPAQ self-report questionnaire underestimated the levels of light PA, total PA and sedentary time in -171.5, -54.8 and -40.6 min / day, respectively. However, IPAQ overestimated the levels of moderate PA and vigorous PA in 91.0 and 47.3 min/day respectively, compared with accelerometry. Compared with normal weight, obese subjects reported higher levels of moderate PA (105.5 and 48.9 min/day, respectively) and vigorous PA (54.1 and 38.3 min/day respectively). Total PA had a greater delta of underestimation between IPAQ and accelerometer measurements in normal weight than in obese subjects (-122.1 vs -16.5 min/day, respectively). Conclusions: The measurement of PA by means of a self-report questionnaire was discrepant with its objective measurement with an accelerometer. The discrepancy is even higher in obese people.
URI
http://repositorio.umayor.cl/xmlui/handle/sibum/8333https://pubmed.ncbi.nlm.nih.gov/32730434/
https://doi.org/10.4067/s0034-98872020000100037
http://repositoriodigital.ucsc.cl/handle/25022009/2074
https://scielo.conicyt.cl/pdf/rmc/v148n1/0717-6163-rmc-148-01-0037.pdf
Coleccion/es a la/s que pertenece:
Si usted es autor(a) de este documento y NO desea que su publicación tenga acceso público en este repositorio, por favor complete el formulario aquí.